Message

Greenstar error codes explained: how to repair your

Feb 24, 2020 · An A1 code (or an A1 281 code) means that your boiler has detected a problem with its water pump. It might be stuck and causing a leak, it might be running with air in the system, or it may have run completely dry.

Get Price

Worcester Bosch Boiler Blocking Error Codes

Boiler Fault Finder Ltd Pine Villa Wolborough Close, Newton Abbot Devon TQ12 1HR . Email: [email protected] Web: boilerfaultfinder.com. Boiler Fault Finder Ltd. Registered in England Number: 8610232

Get Price

How To Reset A Worcester Boiler - Rowlen

Common Fault Codes On Worcester Boilers. Worcester boilers are well made and long-lasting, but, like all boilers, they do have some common faults that you can expect to see during the life of the machine. The most common fault codes include: EA – to tell you that your boiler has not ignited – try to reset before seeking support

Get Price

2021 Worcester Bosch Boiler Error & Fault Codes Explained

This can range from issues such as flashing fault codes (a fault code that flashes on and off on the display screen), continuous fault codes (a fault code that stays on the screen). The Worcester Bosch CDI Classic range has come a long way since the original design.

Get Price

Worcester Boiler Problems: Common Fault Codes + How to Fix

Jun 10, 2020 · There are any number of fault codes your boiler can generate that relate to this issue including D1 286, E5 218, E5 332, E9 219 and E9 224. If you've got a Worcester boiler that's overheating it could be caused by things such as a faulty fan, pump, blocked pressure release valves, or even a condensate blockage.

Get Price

Worcester Bosch Boiler Fault Codes. | Team Boiler

Fault Description System Behaviour; 200 O: Boiler in heating mode: 201 O: Boiler in hot water mode: 202 O: Boiler in anti-cycle mode: 203 0: Boiler in standby – no heat energy demand

Get Price

Worcester Fault Codes | Worcester Bosch Boiler Fault Codes

You should turn off your boiler and contact BOXT or Worcester Bosch to send out an engineer. FB 365. An FB 365 fault code means there is a gas valve leak. You should turn off your boiler and contact BOXT or Worcester Bosch to send out an engineer. A1 281. This means the pump is stuck or running with air in the system.

Get Price

Worcester Bosch A1 281 Fault Code - EPHG Limited

If your Worcester Bosch Boiler is giving you an A1 281 error code it means that your pump is either stuck, or that's running but with air in the system. The

Get Price

8 Common Worcester Bosch Boiler Problems and Faults + FIXES

May 31, 2021 · If you've got a Worcester boiler that's overheating it could be caused by things such as a faulty fan, pump, blocked PRV or even a condensate blockage. Some common overheat fault codes include D1 286, E5 218, E5 332, E9 219 and E9 224.

Get Price

Worcester Boiler Error Codes - ACE Plumbers - Worecester

Local Plumbers Available 24/7 in Maidenhead and Berkshire Area. Worecester Boiler Manuals Emergency Plumber work undertaken Call 01628 369247

Get Price

Worcester Boiler Error Codes [Full 2022 List] - Boiler Central

Fault Code: Cause Code: Fault Description: Possible Cause: Repair Required: A1: 281: Boiler water pump running in air or stuck. Low water in the system or system dry – check boiler pressure gauge and repressurise to 1 bar. If your boiler has lost water pressure then there may be an additional water supply problem. Please call us for a quote. C1: 264

Get Price

Worcester Bosch Greenstar Junior 28i – blue light flashing

Apr 08, 2018 · Worcester Bosch Greenstar Junior 28i – blue light flashing, no heating or hot water Same fault codes can also mean problems with electronics (PCB) or spark generator. First thing to check is to make sure that gas is on. Video below shows the boiler under fault conditions and also working correctly following repair. Previous article

Get Price

A Quick Guide To Fix 8 Worcester Bosch Boiler Error /Fault

Mar 10, 2021 · types of worcester bosch boiler fault codes. fault code: cause code: a1: 281: low water in the system or none at all – check pressure gauge and re-pressurise to 1 bar: c1: 264: fan has stopped working: ea: 227: no flame has been detected – boiler will block during 4 attempts then go to locking fault: ef: 349

Get Price

Worcester Bosch Boiler Problems, Repair Advice & How to Fix

When there's a fault with your Worcester Bosch boiler, the unit will lockout for safety reasons until it has been fixed, which will prevent it from operating but also save it from further damage. There are many possible reasons why a boiler might lockout: flame sensor detector issue, blocked flue or condensate pipe, no or insufficient fuel

Get Price

Worcester Bosch Boiler Fault Codes Guide | H2 Property

Jan 22, 2021 · Use this guide to find out your next steps to fixing your Worcester-Bosch boiler. Worcester Bosch Boiler Fault Codes. A1 281: Pump stuck or running with air in the system: C1 264: Airflow stopped during operation: C4 273: Airflow present during last 24 hour: D1 240: Return sensor short circuit

Get Price

Common Worcester Bosch Boiler Error Codes - iHeat

Feb 24, 2021 · When you see the fault codes for the Heat Control Module (HCM) is defective an engineer needs to be called to check your Worcester BOSCH boiler as it may need replacing. No Flame Signal Due To Blockage or Internal Leak: EA 227. When this code appears on the control box of your Worcester boiler, it can mean several different things.

Get Price

Worcester | Repair Network

Boiler Model Fault Description / Code Reason; Worcester Bosch Greenstar 4000 30: 1021: Cylinder charging or hot water temperature sensor faulty. Turn the appliance off and back on again. The hot water sensor has been changed if an open or short circuit or refitted to the pipe if it has fallen off. Worcester Bosch 4000: 224: Software issue.

Get Price

Worcester Bosch Boiler Issues: Errors and Fault Codes

Hi James, a fault code A1 281 on your Worcester Bosh boiler deals with faulty central heating pump. In short, the central heating pump is either jammed or it is running with an air in the boiler. In case, the pump is jammed, it is expected that the bearings or tube has broken.

Get Price

List Of Worcester Bosch Boiler Error Codes / Fault Codes

Hi James, a fault code A1 281 on your Worcester Bosh boiler deals with faulty central heating pump. In short, the central heating pump is either jammed or it is running with an air in the boiler. In case, the pump is jammed, it is expected that the bearings or tube has broken.

Get Price

Same Day Worcester Bosch Boiler Fault Finding Guildford

Worcester Bosch Boilers Fault Finding in Guildford GU1. Our Worcester Bosch boiler fault finding team in Guildford are Gas Safe registered and ready to help throughout the year. The routine annual boiler servicing can eliminate faults happening as any minor faults are picked up sooner and often dealt with quicker.

Get Price

BOSCH WORCESTER CONDENSING BOILER FAULT CODES

f your Bosch Worcester condensing boiler is showing a fault code it should be listed below, in some cases these can be fixed by the competent DIY'er. A1. PUMP HAS RUN DRY. Check system pressure, add water and then bleed if necessary. A7.

Get Price

Boiler Error Codes - boilerPRO

So your boiler is flashing and its showing a random set of numbers and letters? This is an error code, and each error code is specific to the error.

Get Price

Worcester 28i Junior Problems | DIYnot Forums

Sep 03, 2019 · SORRY. Ok, I am having issues with my 5 year old boiler, Worcester Bosch 28i Junior. Until recently the boiler has been working fine no issues whatsoever since being installed. A Couple of weeks back the red warning light was flashing and the unit was in lockout, I reset and again the red lights flashed (4 times a sec).

Get Price

Worcester Bosch Boiler Error / Fault Codes - Battersea

Incompatible code plug – check if a correct code plug is installed and exchange or reconnect code plug 815 W/B Low loss header temperature sensor faulty – check the sensor port or check the differential sensor for incorrect installation position or breakage

Get Price

Boilers For Your Home | Worcester Bosch

Boilers. Worcester Bosch boilers come in gas, propane (LPG), and oil fuel types so you will definitely find a boiler to suit your home. Select one of the following products for more details before contacting an installer for a quote and advice. We know that buying a new boiler can be a daunting and confusing task.

Get Price

FAQ | Worcester Bosch Boiler

Hi James, a fault code A1 281 on your Worcester Bosh boiler deals with faulty central heating pump. In short, the central heating pump is either jammed or it is running with an air in the boiler. In case, the pump is jammed, it is expected that the bearings or tube has broken.

Get Price

Worcester Bosch Boiler Faults | THS Plumbing & Heating

Worcester Bosch Boiler Faults. Worcester Bosch boilers are one of the UK's most popular, more heard about boiler manufacturers. Worcester Bosch are undoubtedly the most heard about boiler brands with up to 10 year guarantee and have won lots of …

Get Price

Worcester Bosch Boiler Issues: Errors and Fault Codes

Worcester Bosch Boiler Blocking Fault Codes. Fault Code Cause Code Possible Cause; A1: 281: Low or no water in the system – check pressure gauge and re-pressurise to 1 bar: C1: 264: Fan stopped working: EA: 227: No flame detected – boiler will block during 4 attempts before going to a locking fault: EF: 349

Get Price

Worcester Boiler Error Codes 2020 | All Models | Boiler Plan

Worcester Bosch boilers can give us with a lot of information through their fault codes, helping professional engineers get a head start when undertaking a repair. Codes vary between models, with as many as 38 codes helping to provide a picture of what's gone wrong.

Get Price

Worcester Bosch Boiler Issues, Errors and Fault Codes

Jun 03, 2020 · Worcester Bosch Boiler Issues, Errors, and Fault Codes: When a Worcester Bosch boiler starts not to run as it should, it can be frustrating not knowing whether the fault is for you to fix or if it's an issue that requires attention from a Gas Safe engineer. More often than not, the Worcester Bosch boiler […]

Get Price

Worcester Bosch Boiler Fault Codes - Boilerhut

So that you can quickly identify what the fault code means and what should be your next course of action, we have developed the below fault code finders for the Worcester Bosch range. Just click on your boiler from the below list and then search for the fault code that your boiler is displaying or view fault codes that aren't displayed.

Get Price

Common Worcester Boiler Problems - Homecure Plumbers

Oct 02, 2020 · Top 10 Worcester Bosch Boiler Problems. 1. Low boiler pressure. When the system is cool, the pressure gauge on a Worcester boiler should be between 1 – 1.5 (in the green section). Worcester boiler water pressure issues are common, especially for those that have been in use for some time. When water pressure is low on a Worcester boiler it can

Get Price

Worcester boiler fault codes - Purple Plumbing People

Any boiler, whether a Worcester, Vaillant, Baxi, Potterton, Viessmann, Ideal or other brand, will often show you a fault code, usually made up of letters and numbers, such as E28 for example. These fault codes are there to help our engineers locate the problem in a …

Get Price

Worcester Boiler Fault Problems And Cures

Worcester Boiler Error Codes [Full 2021 List] - Boiler Central

Get Price

Worcester Bosch Boiler Problems, Fault and Error Codes

Fault Code: Cause Code: Fault Description: Possible Cause: Repair Required: A1: 281: Boiler water pump running in air or stuck. Low water in the system or system dry – check boiler pressure gauge and repressurise to 1 bar. If your boiler has lost water pressure then there may be an additional water supply problem. Please call us for a quote

Get Price

Common Worcester Bosch Boiler Error Codes & What They Mean

The following fault codes can appear on a Worcester BOSCH Greenstar boiler for various reasons: Fan Speed Error: C6 215 This fault code indicates that the fan speed in your Worcester Greenstar boiler is too high.

Get Price

Worcester Bosch Fault Code A1 – MyBoiler.com

Fault Code Cause Code Possible Cause; A1: 281: Low or no water in the system – check pressure gauge and re-pressurise to 1 bar: C1: 264: Fan stopped working: EA: 227: No flame detected – boiler will block during 4 attempts before going to a locking fault: EF: 349: Boiler operating at minimum burner load and there is a greater flow and return temperature than 18°C

Get Price

Worcester Bosch Boiler Error Codes

EF The boiler is operating at minimum burner load and there is a greater than 18°C Flow & Return temperature difference No Code Air lock or reduced water content – …

Get Price

Boiler Fault Codes - A guide to identifying your boiler's

As accredited installers of the three of the top tried and trusted boiler brands in the UK, Worcester Bosch, Vaillant and Ideal, we have provided a list of the most common fault codes below by brand. So read on to find out which one might be relevant for you.

Get Price

Worcester Bosch Boiler Problems: Fault Codes | Living by

May 13, 2020 · Worcester Bosch fault codes: blocking errors A1: Pump stuck or running in air. Cause code: 281; Possible cause: Little or no water in the system – check pressure gauge and repressurise to 1 bar; C1: Airflow stopped during operation. Cause code: 264; Possible cause: Fan has stopped; EA: No ionisation detected after ignition. Cause code: 227

Get Price

Worcester Bosch Boiler Problems, Fault and Error Codes

The A1 281 fault code on Worcester boilers relates to a problem with the pump. The pump is either stuck, or it's running with air in the system. If the pump is stuck, it's likely that the shaft or bearings have worn out due to old age. When this is the case, you'll need to call a boiler repair engineer to come and replace the shaft and bearings.

Get Price

Worcester Fault Codes - FREE BOILER MANUALS

Fault Description System Behaviour; 200 O: Boiler in heating mode: 201 O: Boiler in hot water mode: 202 O: Boiler in anti-cycle mode: 203 0: Boiler in standby – no heat energy demand

Get Price

What to do if your boiler loses pressure | Worcester Bosch

Attach the hose to each side of the valve and open the mains cold tap. Open the second tap which allows water in to the heating system. Watch the pressure rise and stop once the bar reaches just about one and turn off both taps. Remove the taps from the hose, there will be some water drip out so be mindfull.

Get Price

Worcester Bosch A8 Fault Code Repair – MyBoiler.com

Worcester Bosch A8 Fault Code Repair. Welcome to the fault-codes section of this site. The following table or page contains the information required to help repair and diagnose the fault codes being shown on the boiler display. You may be guided through the fault finding sequence or steps, for rectifying your boiler with this fault code.

Get Price

Worcester Bosch Boiler Error Codes | Herofix

If your Worcester Bosch boiler's on the blink, read on to help diagnose the fault. A quick word of warning before you do: unless you are a qualified heating engineer, do not remove the boiler case, unscrew any panels or remove any parts.

Get Price

Worcester Bosch Boiler A1 281 Error/Fault Code - YouTube

Worcester Boiler Fault Problems And Cures

Get Price

Worcester Bosch Boiler Fault Code A1 281

Worcester Bosch Boiler Issues: Errors and Fault Codes

Get Price

Worcester Fault Codes - heatsurgeon.co.uk

A1 281 The pump is running with air in the system or stuck.Reset your boiler but if the issue persists, contact us for an engineer's help. EF 349 The boiler's operation is at a minimum burner load.Make sure the system pressure is between 1 and 1.5 bar.

Get Price

Worcester Bosch Greenstar I System / Combi Boiler Error Codes

May 03, 2015 · Leave a Comment / Boiler Fault Codes, Worcester Bosch Boilers / By Emergency Plumbers / May 3, 2015 May 3, 2020 / Boiler Fault Codes, Worcester Bosch, A1 281: Pump stock or running dry: E9 224: Flue or high limit thermostat activated: D4 341: Primary flow temperature rising too fast

Get Price

Worcester Bosch Boiler Fault Code Troubleshooter

Boiler Model: Fault Description / Code Reason: Worcester Bosch Greenstar 4000 30: 1021: Common fault, caused by an electrical fault, requires a call out from a Worcester Bosch engineer. Worcester Bosch 4000: 224: Software issue. Arrange a visit from a Worcester Bosch engineer to reset the boiler/PCB.